Detailed Product Description: | Hash PCII ammonia chlorine, chlorine dioxide, chlorine single-parameter water quality analyzer Hach Company introduced 30 a variety of models PCII series of single-parameter water quality analyzer a PCII Series (measurable parameters and measuring range, please refer to Table 2 PCII single parameter water quality analyzer parameter list and Order) applies not only to the wild Field testing of water quality but also for water quality analysis in the laboratory. This series is Hach Company pre-programmed standard curve into a single parameter water quality analysis in a standardized laboratory instrument calibration verification before leaving the factory strictly in accordance with the international standardization of detection methods. This series of one-parameter water quality analyzer for the measurement of one or more parameters can directly display the measurement results. The PCII single-parameter water quality analyzer uses an advanced optical system to expand the range to save the time required for sample dilution analysis greatly improve the efficiency of the colorimeter measurement parameters. The PCII single parameter water quality analyzer main features are as follows: ●? Carrying: weighs only 230 grams; ●? Excellent waterproof performance: dip in water of about 0.9 m up to 30 minutes still normal use; ●? Data logging capabilities: Allows users to store and call the 10 most recent data points without the need to manually record the data; ●? Large-screen display: (1) easy to view the readings on the screen with background lighting when the lighting is dim; (2) the battery indicator icon indicates the battery is easy to replace the battery in a timely manner. Technical indicators: Wave??????? Length: different models differ Photometric range :0-2 .5 ABS Electricity???????? Source: No. 7 alkaline battery Weight???????? Amount: 230g Operating Environment: 10 ~ 50 ℃; 0-90% relative humidity Ordering Guide: The PCII single-parameter water quality analyzer includes the following components: PCII single-parameter water quality analyzers, reagent kits, than the color of the pool and user manual (Order Table 2 PCII single-parameter water quality analyzer measurement parameters and Order) Recommend: 1.58700-00????? Residual chlorine and total chlorine water quality analyzer 2.58700-51????? Chlorine dioxide water quality analyzer 3.58700-40????? Ammonia water quality analyzer 4.58700-05????? Fluoride water quality analyzer 5.58700-04????? Ozone water quality analyzer Table 3? PCII type single-parameter water quality analyzers measure the parameter list and Order Number measurement parameter measurement range (Mg / L) water quality analyzer Order Alachlor (herbicides) immune tube domain value: 0.1ppb, 0.05ppb 28129-00 Spirit of France, two aluminum test aluminum 0.01-0.800 58700-25 3 ammonia salicylate method 0.01-0.800 NH3-N 58700-40 4 chloramines, free ammonia indophenol chloramine :0.04-4 .50 Cl2 Free ammonia :0.02-0 .50 of NH3-N-58700-26 Atrazine Atrazine (Herbicide) immune tube domain values: 0.1,0.5,3.0 ppb 27635-00 6 Bromine DPD method 0.05-4.50/0.2-10 Br2 58700-01 Free chlorine, total chlorine DPD method 0.02-2.00/0.1-8.0 Cl2 58700-00 8 free chlorine, total chlorine, pH DPD method (chlorine) Phenol red (pH) chloride :0.1-10 .0 Cl2 pH :6.0-8 .5 58700-12 9 chlorine the SwifTest dispenser DPD method 0.02-2.00/0.1-8.0Cl2 58700-23 (F) 58700-24 (T) 10 chlorine dioxide DPD / glycine France 0.05-5.00 58700-51 11 Cr (VI) 1,5-Diphenyl hydrazine 0.01-0.70 58700-17 12 copper zinc salts rather 0.04-0.50 58700-19 13 fluoride SPANDS method 0.1-2.0 58700-05 14 the iron FerroVer France 0.02-5.00 58700-22 15 Iron TPTZ method 0.01-1.70 58700-16 16 rapid lead column extraction 5-150ug / L 58700-21 , PAN France, 17 manganese - Low Range 0.01-0.70 58700-18 18 Manganese - periodate oxidation method of high range 0.2-20.0 58700-15 19 acetochlor (herbicide) immune tube domain values: 0.5,2.0 ppb 28134-00 20 molybdate ternary complex method 0.02-3.00/0.1-12.0 58700-10 21 nickel / cobalt the PAN France nickel: 0.01-1.0 Cobalt: 0.02-2.0 58700-20 22 nitrate nitrate nitrate nitrate 23 dissolved oxygen HRDO France 0.2-10.0 58700-03 24 ozone indigo sulfonate method 0.01-0.25/0.1-0.75 58700-04 PCB immunity in 25 soil pipe the value of the jurisdictions: 1,5,10,50 ppb 27734-00 26 phosphate PhosVer 3 0.02-3.0 58700-06 27 the organophosphate PhosVer3 UV-digestion method 0.1-2.5/1-125 58700-07 28 silicon molybdosilicate 1-10058700-34 29 sulfate turbidimetry 2-7058700-29 30 total petroleum hydrocarbons (TPH) in soil in the immune tube domain value: 20,50,100,200 ppb 27750-00 31 water total petroleum hydrocarbons (TPH) immune tube the 2,5,10,20 ppb limits for 27742-00 32 zinc and zinc copper method 0.02-3.0 58700-09 Contact: paint Miss QQ: 1248602809 Hotline: 18862104458 E-mail: Hilda610@yahoo.cn |
Admin>>>
You are the 12387 visitor
Copyright © GuangDong ICP No. 10089450, Suzhou Aung Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 12387 visitor
Copyright © GuangDong ICP No. 10089450, Suzhou Aung Instrument Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility